Indoor switch

Outdoor LV Distribution Box
+
  • Outdoor LV Distribution Box

Outdoor LV Distribution Box

Category:

Keyword: Outdoor LV Distribution Box

Details

With the strong assistance of our adept professionals, we are engrossed in supplying a large variety of Feeder Pillar Panel.The offered panel is Integrated with power distribution/metering/protection/control/reactive power compensation function.

General

This panel is extensively used in commercial and residential sectors for low voltage distribution applications. Before offering to the clients, this panel is stringently tested in order to ensure its flawless performance. Comply with standard IEC439.

Service environment

a) Air temperature: Maximum temperature: +40℃; Minimum temperature:-25℃.

b) Humidity: Monthly average humidity 95%; Daily average humidity 90%.

c) Altitude above sea level: Maximum installation altitude: 2500m.

d) Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.

e) No frequent violent shake.

Product feature

Farady JP feeder pillar enclosure was made of 2mm high quality stainless steel plate after multiple bending flanging process (flame retardant, environmental protection, heat insulation, anti-condensation performance), using special stainless steel welding process, the overall strength after molding, the surface smooth as a mirror, do not leave weld marks; internal installation of beam (plate) for the hot galvanizing process, to ensure that the twenty years do not rust; the front and rear doors, easy operation and maintenance, the door was edged with high elastic aging sealant, each door is equipped with two types of lock, padlock with anti rain cover wall rust; whole closed with a sealing device measuring room; the side of the box is equipped with cable lines into the proof of foreign body wear tube, bottom ventilation holes and the cable outlet hole is arranged at the top of ventilation and screen, waterproof Anti rust, dustproof, anti-foreign object function, protection grade: IP54.

Main technical specifications

No.

Description

 

 

Busbar Rating

A

630 

Metal used for busbars

 

Copper

Type of protection used on busbars against
corrosion (e.g.heavily tinned)

 

Tinned Plating

Dimensions of busbars
length xwidth x thickness

mm

660x50x5

Method of connection between busbars and
cable lugs (cable lugs not to be provided)

 

Bolted Type

Fixing centre of HRC fuse

mm

90 

Are safety barriers fitted between phases of
the same incoming or outgoing unit?

 

Yes

Are insulating shields fitted between
adjacent units?

 

No

Minimum clearance between the lowest
cable connection and ground level

mm

300 

10 

Material used for housing

 

Hot Dipped
Galvanized Sheet

11 

Treatment of housing against atmospheric
corrosion

 

7 Tank Process

12 

Padlocking facility on housing door

 

Yes

13 

Dimensions of complete housing (Root
included)Height x width x depth

mm

1475x1300x500

14 

Weight of complete pillar

 

200kg

Note: For rated current is optional by clients.

Outdoor electrical distribution with advanced technology

Farady low voltage, JP series Feeder Pillars use 304 stainless steel enclosure with IP54 protection degree suitable for outdoor use.

Cost savings

All weatherproof outdoor enclosures allow the equipment to be located in any outdoor environment, freeing up valuable indoor floor space whilst retaining remote operation and control.

There are a wide range of metering instruments available for monitoring the unit locally or remotely, ensuring efficient operation.

JP series Feeder pillars are available as part of a package substation with transformers and MV switch or circuit breakers. Additional cost savings are achieved through direct coupling from the transformer to the JP Feeder pillar eliminating expensive cable runs.

Safety

CCC certified, providing IP54 operator protection under all circumstances during operation, allowing electrical systems to be fully co-ordinated minimising electrical faults. In addition to the overload and short circuit protection, each breaker can be fitted with earth fault protection.

Flexibility

The modular design enables customisation for individual requirements, and has the flexibility to suit the changing needs of the LV distribution system.

Maximum flexibility is achieved by the four pole busbar system up to 3200A and the Compact NS range of moulded circuit breakers of ratings up to 630A.

As a complete unit, the JP Feeder Pillar will not only provide circuit protection, but the outgoing circuits can also be controlled individually via hardwired pilots or linked to the incoming breaker. Other "add-on" benefits include remote monitoring and status of each breaker and also remote operation through motor mechanisms.

Easy installation

The JP Feeder pillar comes complete and factory assembled for easy installation in any outdoor location with bottom entry cable through individual gland plates. The cable space is protected by an earthed metal screen, and each breaker is fitted with cable shrouds to maintain IP2X operator protection when the screen is removed.

Addition of new circuits is made easy, by utilising the cassette on the MCCB breaker allows the breaker to be positioned anywhere on the busbar system before being clamped contributing minimum disruption of supply.

Structure

Outdoor Low Voltage Distribution Box (LVDB)01
Outdoor Low Voltage Distribution Box (LVDB)02

Installation size

Outdoor Low Voltage Distribution Box (LVDB)03

Ordering Instructions

1. Below terms should be marked while ordering:

Incoming and outgoing

With reactive power compensation or not

Protection method(MCCM/ELCB or recloser)

Breaking capacity

Related products

Leave a Message Online


If you are interested in our products, please leave your email address to receive a free product quote. Thank you!